Description
Specifications: Temperature control range: -50 ~ 110 ° C Resolution: -9.9 to 99.9 is 0.1° C , 1 ° C in other ranges Measurement Accuracy: 0.1 ° C Control accuracy: 0.1 ° C Hysteresis accuracy: 0.1 ° C Refresh rate: 0.5 Ssecond Overheat protection: 0 ~ 110 ° C Input power: DC 12V Measuring inputs: NTC (10K 0.5%) waterproof sensor Output: 10 A relay all the way Environmental requirements: -10 ~ 60 degrees Celsius, humidity 20% -85% Power consumption: Static current <=35 MA; Dynamic current <=65 MA Easy and convenient to use Size: Approx. 48 x 40 x 14 mm Total weight: 20 g Package weight: 30 g Operating instructions: Press and hold SET button for 5 seconds to enter the main menu settings. Press the + – keys to toggle from P0 through P8. Press and hold SET for 10 seconds without pressing other key to confirm setting and return. Setting range codes: P0 Cooling / heating C/H C P1 Hysteresis setting 0.5-15 2 P2 Highest setting upper limit 110 110 P3 Lowest setting upper limit -50 -50 P4 Temperature correction -7-7 degrees Celsius 0 P5 Delay start time 0-10 minutes 0 P6 High temperature alarm 0-110 degrees Celsius OFF